R-438A Pressure Temperature Chart
Complete Guide to R-438A Pressure Temperature Chart (PT Chart)
1. Introduction to R-438A Refrigerant
R-438A, also known as MO99, is a non-ozone depleting HFC refrigerant blend designed as a replacement for R-22. It is one of the most widely used retrofit refrigerants due to its excellent oil compatibility and minimal system modification requirement.
Composition of R-438A
R-438A is a blend of:
-
R-32
-
R-125
-
R-134a
-
R-600 (Butane)
-
R-601a (Isopentane)
Applications
-
Residential split AC
-
Packaged air conditioning systems
-
Commercial refrigeration
-
Cold storage units
-
Chillers
2. What is a Pressure Temperature (PT) Chart?
A Pressure Temperature Chart (PT Chart) shows the relationship between:
-
Pressure (PSI)
-
Saturation Temperature
Why It’s Important
-
Converts PSI to temperature
-
Helps calculate superheat & subcooling
-
Ensures proper refrigerant charge
-
Helps diagnose system faults
3. Why R-438A PT Chart is Important
Using the correct PT chart helps:
-
Prevent overcharging
-
Improve system efficiency
-
Reduce compressor failure
-
Ensure accurate troubleshooting
4. Properties of R-438A Refrigerant
| Property | Value |
|---|---|
| Type | Blend |
| ODP | 0 |
| GWP | Medium |
| Glide | Moderate |
| Oil Compatibility | Mineral, POE |
| Replacement For | R-22 |
5. R-438A Pressure Temperature Chart (°F vs PSI)
R-438A PT Chart (°F / PSIG)
| Temperature (°F) | Pressure (PSIG) |
|---|---|
| -40 | 6 |
| -30 | 11 |
| -20 | 17 |
| -10 | 24 |
| 0 | 32 |
| 10 | 41 |
| 20 | 52 |
| 30 | 64 |
| 40 | 78 |
| 50 | 94 |
| 60 | 112 |
| 70 | 132 |
| 80 | 154 |
| 90 | 178 |
| 100 | 204 |
| 110 | 232 |
| 120 | 263 |
| 130 | 296 |
| 140 | 332 |
6. R-438A Pressure Temperature Chart (°C vs PSI)
R-438A PT Chart (°C / PSIG)
| Temperature (°C) | Pressure (PSIG) |
|---|---|
| -40 | 6 |
| -35 | 8 |
| -30 | 11 |
| -25 | 14 |
| -20 | 17 |
| -15 | 20 |
| -10 | 24 |
| -5 | 28 |
| 0 | 32 |
| 5 | 36 |
| 10 | 41 |
| 15 | 46 |
| 20 | 52 |
| 25 | 58 |
| 30 | 64 |
| 35 | 71 |
| 40 | 78 |
| 45 | 86 |
| 50 | 94 |
| 55 | 103 |
| 60 | 112 |
| 65 | 122 |
| 70 | 132 |
7. How to Read an R-438A PT Chart
Steps
-
Measure system pressure
-
Locate pressure in PT chart
-
Convert to saturation temperature
-
Compare with actual pipe temperature
8. Superheat and Subcooling with R-438A
Superheat Formula
Subcooling Formula
Typical Values
-
Superheat: 8°C – 12°C
-
Subcooling: 10°C – 15°C
9. Charging Guidelines for R-438A
Always charge in liquid form.
Best Practices
-
Use digital manifold gauges
-
Charge slowly
-
Monitor superheat & subcooling
-
Avoid overcharging
10. Retrofit from R-22 to R-438A
Steps
-
Recover R-22
-
Replace filter drier
-
Check oil condition
-
Evacuate system
-
Charge R-438A
-
Adjust expansion valve
11. Troubleshooting Using PT Chart
Low Pressure
-
Leak
-
Undercharge
-
Restriction
High Pressure
-
Overcharge
-
Dirty condenser
-
Poor airflow
12. Safety and Handling Guidelines
-
Wear PPE
-
Avoid inhalation
-
Store cylinders properly
-
Follow safety guidelines
13. Advantages and Disadvantages
Advantages
-
Excellent retrofit refrigerant
-
Works with mineral oil
-
No ozone depletion
Disadvantages
-
Temperature glide
-
Slight performance variation
14. Common HVAC Technician Mistakes
- Charging vapor instead of liquid
- Ignoring PT chart
- Wrong superheat calculation
- Overcharging
15. Frequently Asked Questions (FAQ)
Q1. What is R-438A used for?
R-438A is used as a replacement for R-22.
Q2. What is normal pressure of R-438A?
Depends on temperature; refer to PT chart.
Q3. Can R-438A replace R-22 directly?
Yes, with minimal changes.
Q4. Is R-438A safe?
Yes, when handled properly.
Q5. What is superheat range?
8°C–12°C.
16. Conclusion
R-438A (MO99) is one of the best R-22 replacement refrigerants available today. Understanding its pressure-temperature relationship is essential for HVAC technicians.
Using PT charts properly helps:
-
Improve efficiency
-
Reduce breakdowns
-
Ensure proper charging