Buderus Heat Pump Error Codes & Fix Guide

Buderus Heat Pump Error Codes & Fix Guide

Buderus Heat Pump Error Codes & Fix Guide (Complete HVAC Expert Guide)

If your Buderus heat pump is showing an error code, it’s not just a fault—it’s a built-in diagnostic message designed to protect your system and guide troubleshooting. Whether you’re a homeowner, HVAC technician, or dealer, understanding these codes can help you diagnose problems faster, reduce downtime, and improve system performance.

This guide covers Buderus heat pump error codes, causes, fixes, and advanced HVAC troubleshooting methods.


About Buderus Heat Pumps

Buderus is a premium European heating brand and part of Bosch Thermotechnology. Buderus heat pumps (Logatherm series) are widely used for energy-efficient residential and commercial heating systems.

Popular models include:

  • Logatherm WLW series
  • Logatherm WPL series
  • Logatherm WSW geothermal units

1. What Are Buderus Heat Pump Error Codes?

Buderus heat pumps use intelligent control systems (Logamatic controllers) that continuously monitor:

  • Temperature sensors
  • Refrigerant pressure
  • Compressor performance
  • Water circulation
  • Electrical components

When a fault is detected, the system displays:

  • Error Codes (E / F Codes) → System stops or limits operation
  • Warning Codes (A Codes) → Advisory alerts

2. Types of Buderus Heat Pump Faults

Electrical Faults

  • Voltage fluctuations
  • PCB failure
  • Relay damage

Sensor Faults

  • Outdoor temperature sensor
  • Flow/return sensor

 Refrigerant Faults

  • Low refrigerant
  • High pressure
  • Compressor overheating

Hydraulic Faults

  • Low water pressure
  • Pump failure
  • Air in system

 Communication Faults

  • Indoor ↔ outdoor communication issue
  • Controller malfunction

3. Complete Buderus Heat Pump Error Code List


Critical Error Codes

Code Description
E01 Flow temperature sensor fault
E02 Return temperature sensor fault
E03 Outdoor sensor fault
E04 Evaporator sensor fault
E05 Condenser sensor fault
E06 Discharge temperature fault
E07 Defrost sensor fault
E08 DHW sensor fault
E09 Flow switch error
E10 High pressure fault
E11 Low pressure fault
E12 Compressor overload
E13 Expansion valve fault
E14 Defrost failure
E15 Freeze protection active
E16 Pump failure
E17 Communication error
E18 Voltage fault
E19 PCB fault
E20 General system fault

 Warning Codes

Code Description
A01 Temporary interruption
A02 Defrost active
A03 Compressor delay
A04 Anti-freeze mode
A05 System optimization

4. Common Buderus Error Codes Explained


 E10 – High Pressure Fault

Causes:

  • Dirty condenser coil
  • Blocked airflow
  • Overcharged refrigerant

Fix:

  • Clean outdoor unit
  • Check fan motor
  • Adjust refrigerant charge

 E11 – Low Pressure Fault

Causes:

  • Refrigerant leak
  • Expansion valve blockage

Fix:

  • Leak detection
  • Recharge refrigerant

E09 – Flow Switch Error

Causes:

  • Low water flow
  • Blocked filter

Fix:

  • Clean strainer
  • Check pump

 E12 – Compressor Overload

Causes:

  • High pressure
  • Electrical imbalance

Fix:

  • Check compressor amps
  • Inspect capacitor

 E17 – Communication Error

Causes:

  • Wiring issue
  • PCB failure

Fix:

  • Inspect connections
  • Replace board

E16 – Pump Failure

Causes:

  • Mechanical issue
  • Electrical failure

Fix:

  • Check voltage
  • Replace pump

5. Advanced Troubleshooting Workflow

Step 1: Identify Error Code

Read from display or controller.

Step 2: Reset System

  • Turn OFF power
  • Wait 5 minutes
  • Restart

Step 3: Basic Inspection

  • Power supply
  • Water pressure
  • Filters

Step 4: Sensor Testing

  • Measure resistance
  • Compare with chart

Step 5: Refrigerant Diagnosis

  • Check pressure gauges
  • Inspect for leaks

6. Sensor Fault Diagnosis

Buderus systems use NTC sensors.

Common Issues:

  • Open circuit
  • Short circuit

Testing:

  • Multimeter
  • Temperature vs resistance

7. Refrigerant & Pressure Issues

Symptoms:

  • Poor heating
  • Ice formation
  • Frequent shutdown

Causes:

  • Gas leak
  • Dirty evaporator
  • Expansion valve issue

Fix:

  • Leak repair
  • Recharge system
  • Clean coils

8. Electrical & PCB Faults

Common Codes:

  • E17
  • E18
  • E19

Causes:

  • Voltage fluctuation
  • PCB damage

Fix:

  • Install stabilizer
  • Replace PCB

9. Communication Errors

Causes:

  • Wiring faults
  • Controller issues

Fix:

  • Check cables
  • Replace modules

10. How to Reset Buderus Heat Pump

Method 1:

Use reset button

Method 2:

Power OFF → Wait → ON

Method 3:

Reset via controller


11. Preventive Maintenance Checklist

Monthly:

  • Check pressure
  • Clean filters

 Quarterly:

  • Inspect wiring
  • Test sensors

 Yearly:

  • Full servicing
  • Refrigerant check

12. Pro HVAC Diagnostic Tips

Since you’re an HVAC professional, here are expert-level insights:

Superheat & Subcooling

  • High superheat → low charge
  • Low superheat → flooding

 Delta T Monitoring

  • Ideal: 5–10°C

Compressor Amp Check

  • High amps → mechanical issue

 Multi-Symptom Logic

  • High pressure + low airflow → dirty condenser
  • Low pressure + frost → refrigerant leak

13. FAQ Section

Q1. What does E10 mean on Buderus heat pump?

It indicates high refrigerant pressure due to airflow restriction or overcharging.

Q2. How do I reset a Buderus heat pump?

Turn off power, wait 5 minutes, and restart.

Q3. Why does low pressure error occur?

Due to refrigerant leaks or expansion valve faults.

Q4. Can I fix error codes myself?

Basic issues can be fixed, but complex faults require professionals.

Q5. How often should servicing be done?

At least once per year.


Final Thoughts

Buderus heat pumps are highly reliable systems backed by Bosch engineering. However, understanding error codes is essential for fast diagnosis, efficient repair, and long-term system performance.

This guide gives you a complete professional-level troubleshooting framework for Buderus heat pumps.

Leave a Reply

Your email address will not be published. Required fields are marked *

Index