Weishaupt Heat Pump Error Codes & Fix Guide

Weishaupt Heat Pump Error Codes & Fix Guide

Weishaupt Heat Pump Error Codes & Fix Guide (Ultimate HVAC Guide)

When a Weishaupt heat pump displays an error code, it’s not just a fault—it’s a high-precision diagnostic alert designed to protect the system and guide troubleshooting. Understanding these codes can help HVAC professionals and homeowners quickly identify issues, reduce downtime, and avoid expensive repairs.

This guide covers everything you need to know about Weishaupt heat pump error codes, causes, fixes, and advanced troubleshooting techniques.


About Weishaupt Heat Pumps

Weishaupt Group is a premium German manufacturer known for high-quality heating systems, burners, and heat pumps. Their heat pump range (like WWP, WWP LB, and Biblock series) is widely used in Europe for efficient and reliable heating solutions.


1. What Are Weishaupt Heat Pump Error Codes?

Weishaupt heat pumps use advanced controllers that continuously monitor:

  • Temperature sensors
  • Refrigerant pressure
  • Compressor operation
  • Water circulation
  • Electrical systems

When a fault occurs, the system displays:

  • F Codes / E Codes → Critical faults
  • A Codes → Warnings or advisory messages

2. Types of Weishaupt Heat Pump Faults

 Electrical Faults

  • Voltage fluctuation
  • PCB malfunction
  • Relay issues

Sensor Faults

  • Outdoor sensor failure
  • Flow/return sensor issues

Refrigerant Faults

  • Low refrigerant charge
  • High pressure
  • Compressor overheating

Hydraulic Faults

  • Low water flow
  • Pump failure
  • Air in system

Communication Faults

  • Controller communication error
  • Bus system failure

3. Complete Weishaupt Heat Pump Error Code List


Critical Error Codes

Code Description
F01 Flow temperature sensor fault
F02 Return temperature sensor fault
F03 Outdoor temperature sensor fault
F04 Evaporator sensor fault
F05 Condenser sensor fault
F06 Discharge temperature fault
F07 Defrost sensor fault
F08 DHW sensor fault
F09 Flow switch error
F10 High pressure fault
F11 Low pressure fault
F12 Compressor overload
F13 Expansion valve fault
F14 Defrost failure
F15 Freeze protection active
F16 Pump failure
F17 Communication error
F18 Voltage fault
F19 PCB fault
F20 General system fault

Warning Codes

Code Description
A01 Temporary interruption
A02 Defrost mode active
A03 Compressor delay
A04 Anti-freeze mode
A05 System optimization

4. Common Weishaupt Error Codes Explained


 F10 – High Pressure Fault

Causes:

  • Dirty condenser
  • Blocked airflow
  • Overcharged refrigerant

Fix:

  • Clean outdoor unit
  • Check fan motor
  • Adjust refrigerant charge

F11 – Low Pressure Fault

Causes:

  • Refrigerant leak
  • Expansion valve issue

Fix:

  • Leak detection
  • Recharge refrigerant

F09 – Flow Switch Error

Causes:

  • Low water flow
  • Blocked filter

Fix:

  • Clean strainers
  • Check pump

F12 – Compressor Overload

Causes:

  • High pressure
  • Electrical imbalance

Fix:

  • Check compressor current
  • Inspect capacitor

 F17 – Communication Error

Causes:

  • Wiring issue
  • PCB failure

Fix:

  • Inspect connections
  • Replace board

 F16 – Pump Failure

Causes:

  • Mechanical failure
  • Electrical issue

Fix:

  • Check voltage
  • Replace pump

5. Advanced Troubleshooting Workflow

Step 1: Identify Error Code

Check display panel.

Step 2: Reset System

  • Turn OFF power
  • Wait 5 minutes
  • Restart

Step 3: Basic Inspection

  • Power supply
  • Water pressure
  • Filters

Step 4: Sensor Testing

  • Measure resistance
  • Compare with chart

Step 5: Refrigerant Diagnosis

  • Check pressure gauges
  • Inspect for leaks

6. Sensor Fault Diagnosis

Weishaupt systems use NTC sensors.

Common Issues:

  • Open circuit
  • Short circuit

Testing:

  • Multimeter
  • Compare resistance vs temperature

7. Refrigerant & Pressure Issues

Symptoms:

  • Poor heating
  • Ice formation
  • Frequent shutdown

Causes:

  • Gas leak
  • Dirty coils
  • Expansion valve issue

Fix:

  • Leak repair
  • Recharge system
  • Clean coils

8. Electrical & PCB Faults

Common Codes:

  • F17
  • F18
  • F19

Causes:

  • Voltage fluctuation
  • PCB damage

Fix:

  • Install stabilizer
  • Replace PCB

9. Communication Errors

Causes:

  • Wiring faults
  • Controller issues

Fix:

  • Check cables
  • Replace modules

10. How to Reset Weishaupt Heat Pump

Method 1:

Use reset button

Method 2:

Power OFF → Wait → ON

Method 3:

Reset via controller


11. Preventive Maintenance Checklist

Monthly:

  • Check pressure
  • Clean filters

 Quarterly:

  • Inspect wiring
  • Test sensors

Yearly:

  • Full servicing
  • Refrigerant inspection

12. Pro HVAC Diagnostic Tips

Since you’re an HVAC professional, here are expert-level insights:

Superheat & Subcooling

  • High superheat → low charge
  • Low superheat → flooding

Delta T Monitoring

  • Ideal: 5–10°C

Compressor Amp Check

  • High amps → mechanical issue

Multi-Symptom Diagnosis

  • High pressure + low airflow → dirty condenser
  • Low pressure + frost → refrigerant leak

13. FAQ Section

Q1. What does F10 mean on Weishaupt heat pump?

It indicates high refrigerant pressure due to airflow restriction or overcharging.

Q2. How do I reset a Weishaupt heat pump?

Turn off power, wait 5 minutes, and restart.

Q3. Why does low pressure error occur?

Due to refrigerant leaks or expansion valve problems.

Q4. Can I fix error codes myself?

Basic issues can be fixed, but complex faults require professionals.

Q5. How often should servicing be done?

At least once per year.


Final Thoughts

Weishaupt heat pumps are premium systems known for durability and precision engineering. However, understanding error codes is essential for fast diagnostics, efficient servicing, and long-term reliability.

This guide gives you a complete professional troubleshooting framework to diagnose and fix Weishaupt heat pump issues effectively.

Leave a Reply

Your email address will not be published. Required fields are marked *

Index